Novolac Epoxy Flooring: When Standard Epoxy Isn’t Enough for Chemical Exposure
A standard epoxy floor handles a lot. It resists abrasion, cleans easily and protects concrete from oils, grease and everyday spills. But in some facilities, a floor is exposed to something harsher: concentrated acids, aggressive solvents, or chemicals stored and transferred in volume.
In those environments, a standard epoxy can soften, stain, blister or lose adhesion, sometimes within months. This is where novolac epoxy flooring comes in.
This guide explains what novolac epoxy is, how it differs from standard epoxy, where it makes sense, and what to consider when specifying a chemical resistant floor coating for your site.
What Is Novolac Epoxy?
Epoxy coatings form when a resin reacts with a hardener to create a hard, cross-linked film. Standard industrial epoxies are typically based on bisphenol resins.
Novolac epoxy uses a different resin backbone. It is built from phenol-formaldehyde chemistry, which gives each molecule more reactive sites. That produces a more densely cross-linked film once cured.
The practical result is a coating that tends to offer:
- Higher resistance to aggressive chemicals, including many acids and solvents
- Better performance at elevated temperatures
- A hard, abrasion-resistant surface
- Longer service life in chemically demanding areas
Wagon Paints’ Rhinofloor range includes chemical resistant novolac epoxy systems alongside its wider epoxy and polyurethane floor coatings, so there is a path from general-purpose flooring through to specialist chemical protection.
Standard Epoxy vs Novolac Epoxy
| Factor | Standard epoxy | Novolac epoxy |
| Chemical resistance | Good against many common chemicals, oils and cleaning agents | Higher resistance, including too many acids and solvents that can attack standard epoxy |
| Heat and thermal exposure | Moderate | Generally better tolerance of elevated temperatures |
| Flexibility | Generally more forgiving | Often harder and less flexible |
| Colour and appearance | Wide colour range | Colour choice can be more limited, and some products darken under UV |
| Typical use | Warehouses, workshops, showrooms, light to heavy industrial | Chemical storage, bunds, battery rooms, process areas |
| Cost | Lower | Typically higher, justified where chemical exposure is the main risk |
Novolac is not automatically the better choice for every floor. If chemical exposure is minimal, a quality standard epoxy system is often the more practical and economical option. Our guide to choosing an epoxy topcoat for high-traffic floors explains how to match a topcoat to traffic and use.
Where Novolac Epoxy Flooring Is Used
Novolac systems are typically specified where chemical contact is frequent, concentrated or hard to control:
- Chemical storage areas and bunded zones: floors that must withstand spills and contain them
- Secondary containment: where regulations or site risk assessments call for chemical-resistant containment surfaces
- Battery rooms: exposure to acid electrolyte
- Manufacturing and processing plants: areas using process chemicals, cleaners and solvents
- Food and beverage facilities: exposure to organic acids, sugars and aggressive sanitising agents, often combined with hot washdowns
- Laboratories and workshops: regular contact with reagents, fuels and brake fluids
- Water and wastewater treatment areas: dosing chemicals and cleaning agents
In storage and handling areas, sites often need to consider standards such as AS 1940 for flammable and combustible liquids and AS/NZS 3780 for corrosive substances. Confirm which requirements apply to your site with a qualified professional.
What to Consider When Specifying a Chemical Resistant Floor
Choosing a chemical resistant floor coating starts with the chemicals themselves, not the coating.
1. Which Chemicals, and at What Concentration?
Chemical resistance is specific. A coating that handles one acid at 10 per cent may not handle another at 98 per cent. List every chemical the floor may meet, including cleaning products, and check each against the coating’s chemical resistance chart.
2. Splash, Spill or Immersion?
There is a big difference between a floor that gets occasional splashes, one that is regularly flooded, and one that must act as secondary containment holding liquid for extended periods. The exposure type and duration should drive the system choice and thickness.
3. Temperature and Thermal Shock
Hot washdowns, steam cleaning and hot process liquids put extra stress on a floor. Check the maximum service temperature and its tolerance of sudden temperature changes.
4. Mechanical Loads
Forklifts, pallet trucks and heavy foot traffic all wear a floor. Chemical resistance means little if the surface is abraded away, so the system needs to suit both.
5. Slip Resistance
Chemical areas are often wet or contaminated. A gloss, smooth novolac finish may need anti-slip aggregate to keep the floor safe. Our overview of epoxy floor coatings and industrial safety explains why slip performance matters.
6. Substrate and Surface Preparation
Even the most chemically resistant coating will fail if it does not bond to the slab. The concrete must be sound, clean and correctly profiled, and free of contaminants. See why surface preparation makes or breaks a coating job.
7. Cure Time Before Chemical Contact
A novolac floor needs to fully cure before it sees chemicals. Follow the data sheet for the required cure period, and plan downtime accordingly. Putting a floor into service too early is a common cause of premature damage.
Common Mistakes With Chemical Resistant Floors
- Choosing a standard epoxy for an area that sees aggressive chemicals
- Specifying from a general brochure rather than a chemical resistance chart for each chemical
- Ignoring cleaning chemicals and washdown temperatures
- Skipping slip resistance on smooth, glossy surfaces
- Rushing cure time to return the area to service
- Leaving spills to sit. Even a resistant floor performs best when spills are cleaned promptly
Looking After a Novolac Floor
A chemical resistant floor still needs routine care. Clean spills promptly, inspect joints and edges regularly, and repair damage early before chemicals can reach the concrete. Our tips on extending the lifespan of your coatings apply here as well.
Get a Chemical Resistant Floor Specified Properly
The right floor for a chemical area starts with the right information. Before you choose a system, list the chemicals your floor will see, their concentrations, temperatures and how they contact the floor.
The Wagon Paints team has supplied epoxy floor systems through its Rhinofloor division for decades, and can help you match a system to your chemicals, substrate and operating conditions. Browse the system selector to explore options, or send us your details for a tailored recommendation.
Contact the Wagon Paints team or call (03) 9729 1344 to discuss your chemical resistant flooring project.